Back to the list

TT-1398 Thermoregulator for pressurized water

Thermorégulateur TT-1398 : Appareil puissant et compact à eau surpressée, pour petits outillages | Domaine d'application : Avec de l'eau jusqu'à 140°C ...Read more

Technical data :

Temperature range : Water up to 140°C
Temperature controller : MP-888 self-adjusting controller with digital display of desired and actual temperature. Automatic temperature control.
Flow control : Electronic, with digital display of flow rate and minimum flow monitoring.
Heating capacity 6 kW : 3/3 stage switching
Pump capacity : 1.3 kW motor, max. 4 bar / max. 40 l/min.
Filling : Automatic
Connections : Heat transfer circuit : 1⁄2″ female thread, Cooling water : 3⁄8″ female thread, Inlet with water filter 3⁄8″ female thread
Dimensions (L×W×H) : 680 × 305 × 760 mm, including casters
Weight : approx. 70 kg empty
Color : Silver gray RAL 7001


All known voltages are available from 3 x 200 V to 3 x 600 V in 50/60 Hz. UL/CSA compliant units also available. For the U.S. market, units are equipped with U.S. inch (NPT) connections and the temperature controller is factory adjusted in degrees F.

 

Standard features :

      • Self-adjusting controller with digital indication of desired and actual temperature. High control accuracy, display to 1/10 of a degree. Adjustable in °C or °F.
      • Automatic temperature monitoring. Alarm is activated when the actual temperature deviates from the desired temperature.
      • Digital flow rate display and minimum flow rate monitoring.
      • Display of system pressure.
      • Automatic pressure relief, venting and filling.
      • Non-scaling heat exchanger.
      • Standard pump with mechanical seal.
      • All components in contact with water are made of stainless steel or bronze.
      • Heater switching in stages.
      • Safety devices :
               > Level control for protection against dry running.
               > Electronic temperature limitation in the controller and separate safety thermostat.
               > Main switch, transformer and motor protection switch.
               > Audible fault alarm
      • All faults are indicated visually.
      • Unit on wheels.


Option :
MP-988 controller, including more than 30 digital interfaces as standard: RS-232, RS-485, Current Loop 20mA, CAN-bus, Profibus etc.